Manufacturer of Induction Furnaces, Induction Melting Furnace, Induction Heating Furnace, Induction Heating Machines, Heating Equipments

-: PRODUCTS :-

Power System Panel (M.F.Generator)

  Supermelt - LI Power System :
Induction Furnace
Supermelt LI Power System
 
a

Melt rate and Power Consumption with hot lining and dense and clean scrape.

a

KVA (input) is the Power requirement for Furnace alone.

a

Voltage (input) 3 Phase, 50 Hz.

a

Power Factor (Line) always more than 0.95.

a

For Melt rate of other metals multiply rate of Steel by, 1 for Aluminum, 1.6 for Copper, 1.8 for Bronze.

 

PRIMARY ISOLATED SUPERMELT - LI POWER SYSTEM
TECHNICAL SPECIFICATIONS 
PERFORMANCE DETAILS FOR MELTING OF FERROUS ALLOYS

KW
CAPACITY SIZE

FREQ
HZ

INPUT

MELT RATE
(KG /HOUR)

CONSUMPTION
(KWH/TON)

CRUCIBLE CAPACITY KG.

 

KVA

Volts

Steel

C.I

Steel

C.I

1

2

3

 

 

#

1650°C

1480°C

1650°C

1480°C

Kg.

Kg.

Kg.

75

3000/1000

85

415

112

125

775

690

25

50

100

125

3000/1000

140

415

195

216

712

645

50

100

150

150

3000/1000

168

415

243

270

690

623

100

150

200

175

3000/1000

195

415

290

322

686

614

150

200

250

250

1000/500

280

415/550

445

490

637

575

300

500

-

350

1000/500

390

415/550

650

700

610

560

500

750

1000

450

1000/500

500

415/550

850

935

601

550

500

750

1000

550

1000/500

610

415/550

1025

1125

594

535

750

1000

1500

 
# Line Isolated Voltage (Primary Isolation)
 

 

 